Main Functions:
1.The working temperature of this Cable Locator is 0-40°C (32-104°F).
2.To avoid damage , this device should be protected against excessive mechanical vibration during handling or use, especially dropping.
3.Only professionals are allowed to calibrate and repair this instrument.
4.Prior to usage, inspect the instrument and the test lead in use for external damage.Please ensure that the instrument and the test lead in use are in tact. The instrument should not be used unless all the functions of the instrument are well prepared for work.
5. When using the instrument, the rated voltage of the tested line should not exceed therated voltage specified in the technical specifications of this Cable Locator.
6.Keep the instrument off direct sunlight to ensure perfect functioning and long lifespan
7.If the instrument is subject to an extremely high electro magnetic field, its functioning ability may be impacted.
8.Only use batteries as described in the technical data section.
1 ) Before using a locator that has been placed or transported under extreme climate conditions, please place it under a new favorable environment for a certain period.
2 ) When the transmitter is connected with live mains , if the Grounding hole of the transmitter is connected with protective ground phase, the current leakage (if any) in the power supply line may join the circuit current of the transmitter, leading to tripping of the leakage circuit breaker, i.e. tripping of FI/RCD.
3 ) Please maintain the original package well for later mailing (such as for calibrationof the instrument).
Main Features:
----- Detecting cables, electrical lines,water/gas supply pipe lines buried in wall or earth;
----- Detecting interruptions and short circuit in cables and electrical lines buried in wall or earth;
----- Detecting fuses and assigning current circuits;
----- Tracing sockets and distribution sockets having accidentally been covered by plastering;
----- Detecting interruptions and short-circuits in floor heating;
----- The transmitter is integrated with the function of AC/DC voltmeter, which can measure12 to 400V AC/DC voltage on a linear basis:
~~~~~~~~~ AC: 12~400V (50 to 60 Hz)土2.5%
~~~~~~~~~ DC: 12~400V±2.5%
The screen of the transmitter can display preset transmitting power, transmitted codes,its own battery energy, mains voltage detected,AC/DC status of mains voltage detected,and warning symbol for main voltage.
The transmitter has the function of self-inspection to detect its own working statusand to display it on the LCD screen for user's reference.
The screen of the receiver can display the transmitting power of the transmitter,transmitted codes, energy of the transmitter's and its own batteries,AC voltage inducedsignal detected and warning symbol for mains voltage.
The sensitivity of the receiver can be adjusted either manually or automatically.The receiver can sweep frequency automatically.
Both the transmitter and the receiver can work under mute mode.
The receiver is available with automatic shutdown (It is powered off automatically over 15 minutes of absence of key stroke).
The receiver's LCD screen is provided with backlight for application in poor light.Both the transmitter and the receiver is provided with flash light function whenworking in darkness.
Additional transmitters are available to extend or distinguish several signals.Compactness, durability and portability.
Copyright © 2022 SHENZHEN NOYAFA ELECTRONIC CO.,LIMITED - www.noyafa.net All Rights Reserved.