The cable fault test operation should be carried out according to the following 3-step procedure!

2022/05/24

Author: Noyafa–POE Tester

Cable fault test The operation should be carried out according to the following 3-step procedure! When using the cable fault tester to test the cable fault, the manufacturer of the cable fault tester should follow the following procedures: The manufacturer of the cable fault tester 1. The multimeter, the shaker or the cable fault test operation should follow the following 3-step procedure. conduct! When using the cable fault tester to test the cable fault, the manufacturer of the cable fault tester should follow the following procedures: 1. The multimeter, the shaker or the cable pre-test results to determine the nature of the cable fault. 2. Select the appropriate test method according to the nature of the cable fault: the pulse method is best for low-resistance faults and open-circuit faults. Of course, the flashover method can also be used for low-resistance faults. Leakage high resistance faults are best to use the flashover method (Rush L method), and some leaky high resistance faults can also use the direct flash method, but usually do not do this, it is best to use the direct flash method for flashover high resistance faults. You can also use both methods to measure and compare with each other to improve the accuracy of judgment.

3. Select the working ground point, and draw two ground wires from the selected ground point, one is connected to the ground of the instrument, and the other is connected to the ground of the high-voltage equipment. The selection principle of the working ground wire of the cable fault tester manufacturer is to ensure that the test phase and it form a closed loop, so that the instrument can obtain the correct test waveform. It should also be noted that the working ground wire must be connected with the system ground, and the cable fault tester makes the human, instrument ground, high-voltage equipment ground and the tested cable ground in the same place.

To ensure personal safety and equipment integrity. If the cable is faulty between phases, the working ground wire must be one of the phase wires, and the phase wire used as the ground wire must be connected to the system ground. For cables with lead-free bushings, the vast majority of faults are discharges to earth or space during high-voltage flashover tests.

Cable fault tester manufacturer Shenzhen Noyafa Electronic Technology Co., Ltd.

CONTACT US
Just tell us your requirements, we can do more than you can imagine.
Send your inquiry

Send your inquiry

Choose a different language
English
Magyar
Ελληνικά
한국어
Türkçe
русский
italiano
Español
Português
Polski
français
Deutsch
日本語
Nederlands
Tiếng Việt
ภาษาไทย
Latin
العربية
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
norsk
Chicheŵa
ਪੰਜਾਬੀ
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
Pilipino
Українська
اردو
O'zbek
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English