Rough measurement of cable fault points

2022/06/14

Author: Noyafa–Cable Tester Manufacturer

The rough measurement of the cable fault point of the cable fault comprehensive tester The rough measurement of the cable fault point of the cable fault comprehensive tester is not afraid of measuring the deviation from the fault point to either end of the cable. This procedure is necessary for fault fixing. The long method of rough measurement is very sharp. According to the basic principle, there are two types, one is the bridge method, and the other is the polarization reflection method. The customary rough measurement method is to convert high-resistance faults into low-resistance faults through burn-through, and then use the bridge method or line voltage pulse reflection method to measure.

Recently, domestic and foreign people attach great importance to the detection of cable faults, and they have successively learned from tourists such as weaving long methods. Now when using the flash tester to detect cable faults, it is no longer necessary to burn through the high resistance, which is enough to directly apply DC to the fault point or shock the ultra-high voltage to make it flashover, and then measure the fault point through the flashover pulse. s position. The DC bridge method is the earliest method to detect cable faults, and it has been a crucial method for detecting cable faults for many years.

For low-resistance grounding and phase-to-phase stuck neck faults, this method is still widely used at present, and the accuracy is high. Similar to ensure that the fault point resistance does not exceed 100kΩ, usually in 2kΩLower is appropriate. Introduce the core resistances on both sides of the cable fault point into the DC bridge and measure the ratio.

From the measured ratio and the cable length, the deviation from the measurement point to the fault point can be calculated. In the figure, RL is the single-core resistance of the cable with a high slope, and RX is the resistance from the beginning to the fault point. By measuring the resistance RX, the distance X from the starting end to the fault point can be calculated.

When the electric bridge method is used to roughly measure the fault point of the cable, the single-arm electric bridge, the arm electric bridge, etc. are commonly used, and the cable flaw detector is also made according to the electric bridge law. Cable fault comprehensive tester for rough measurement of cable fault points Shenzhen Noyafa Electronic Technology Co., Ltd.

CONTACT US
Just tell us your requirements, we can do more than you can imagine.
Send your inquiry

Send your inquiry

Choose a different language
English
Magyar
Ελληνικά
한국어
Türkçe
русский
italiano
Español
Português
Polski
français
Deutsch
日本語
Nederlands
Tiếng Việt
ภาษาไทย
Latin
العربية
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
norsk
Chicheŵa
ਪੰਜਾਬੀ
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
Pilipino
Українська
اردو
O'zbek
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English