Four Judgment Methods of Power Cable Fault Points

2022/06/14

Author: Noyafa–Cable Tester Manufacturer

Four methods of judging the fault point of the power cable. When the cable or the middle of the cable has a balance point fault, it is difficult to visually see the white point due to the installation of the external insulation. specified location. 1. The method of digital multimeter method without damage to the wire: First, connect one side of the wire with the segment point to the 220V live wire, and make the other end hollow. Adjust the gear of the multimeter to the AC 2V voltage gear.

The next scene starts from the swarms of former enemies of the faulty cable, holding a black test lead in one hand, and the red test lead slowly sliding along the insulation layer of the faulty cable. The voltage value at the unbroken point of the cable is about 0.445V. When the red test lead moves somewhere, the voltage value displayed by the multimeter plummets to 1/10 of the normal voltage, that is, 0.04V.

At this time, the breakpoint can basically be determined to be 15cm in front of the post (the end of the fire line in groups). 2. The method of induction tag electric pen first removes the wires around the breakpoint wire and has power supply, and then connects the cable with the breakpoint to the live wire, the next field uses induction purple hair to move slowly perpendicular to the wire, when the AC signal of the induction row pen When it converges, it can be judged that the breakpoint is at the detection point, and the error is at most not exceeding 10cm. 3. The broken line method can not use the bending method to test the breakpoint of this short wire, and connect the two wires to the two sides of the red and black test pens of the multimeter respectively.

From one side of the wire, the curtain is bent and if the multimeter is on and off at this time, then the breaking point is here. Follow this method until the breakpoint is reached. 4. Acupuncture identification method This method is to use the on-off of the cable to check the breakpoint of the wire.

Divide the breakpoint wire and insert the steel needle upside down, and then use a multimeter to measure the on-off phenomenon in turn. The difference is the breakpoint everywhere. However, this method will destroy the insulating layer, and it is easy to induce other problems in the later cable service.

Four judgment methods of power cable fault point

CONTACT US
Just tell us your requirements, we can do more than you can imagine.
Send your inquiry

Send your inquiry

Choose a different language
English
Magyar
Ελληνικά
한국어
Türkçe
русский
italiano
Español
Português
Polski
français
Deutsch
日本語
Nederlands
Tiếng Việt
ภาษาไทย
Latin
العربية
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
norsk
Chicheŵa
ਪੰਜਾਬੀ
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
Pilipino
Українська
اردو
O'zbek
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English