Classification of cable fault properties

2022/06/14

Author: Noyafa–Cable Tester Manufacturer

Cable fault finding Cable fault property classification Cable fault finding Power cable faults are caused by damaged electrical insulation of the cables, and the projects of vivid faults are generally divided into two categories: low-resistance blocking, excavation and congestion faults; high-resistance faults wind and flashover faults. Low-resistance faults, where the insulation resistance at the fault point of the cable drops to the characteristic impedance of the cable, or even the faults with zero DC resistance, are called low-resistance faults or plugging faults (Note: This definition is from the perspective of applying the pulse mapping method, considering the Due to the influence of the different wave impedance on the polarity change of the reflected pulse, for this railway bridge method, the concept of low-resistance fault is not limited by the definition of characteristic impedance) Here is a reference value of cable characteristic impedance: aluminum The characteristic impedance of a power cable with a cross-sectional area of ​​240m2 is about 10Ω, the characteristic impedance of the power cable of the profiler with aluminum core 35m2 is about 40ΩThe characteristic impedance of aluminum core power cables of any cross-sectional area can be calculated carefully. Generally, the cable resistance is infinite or the insulation resistance value of the normal cable is the same, but the voltage can never be fed to the user. The faults in which the DC resistance at the fault point of the resistance fault cable overwhelms the characteristic impedance of the cable are all high resistance faults. Leakage fault When the cable is quenched and tested for insulation, the leakage current increases with the increase of the test voltage.

When the test voltage rises sharply to the rated value (sometimes far reaching the default rated value), the leakage current exceeds the allowable value. The indicator value of the degree meter rises steadily, and the needle shakes in a flashover manner. When the voltage drops slightly, this phenomenon disappears, but the cable insulation still has a very high resistance value, which indicates that the cable is faulty. And this kind of failure point never distributes the floodway to Qin Muchu resistance, unless the failure after the discharge of tea or wine or the external failure of the flashover is called a flashover failure. Classification of cable faults Cable fault finding Shenzhen Noyafa Electronic Technology Co., Ltd.

CONTACT US
Just tell us your requirements, we can do more than you can imagine.
Send your inquiry

Send your inquiry

Choose a different language
English
Magyar
Ελληνικά
한국어
Türkçe
русский
italiano
Español
Português
Polski
français
Deutsch
日本語
Nederlands
Tiếng Việt
ภาษาไทย
Latin
العربية
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
norsk
Chicheŵa
ਪੰਜਾਬੀ
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
Pilipino
Українська
اردو
O'zbek
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English